The USB Thermocouple data logger accepts any Type K, J or T Thermocouple wire. Depending on the thermocouple, the logger can measure and record temperatures from -200°C. Using the software, thermocouple type, thermocouple calibration, sampling rate, start-time, logging mode, and downloading and analysis of data can all be performed. The data logger features a user-replaceable battery, high and low alarm settings, LEDs to show status of logging and USB interface for fast data download.
The datalogger comes with a long-life lithium battery, as well as red, green, and orange LED status indicators. Temperature measurement ranges include: -130°C to +900°C for a J type thermocouple, and -200°C to +1300°C for a K type thermocouple, and -200°C to +350°C for a T type thermocouple. Temperature resolution is 0.5°C, and accuracy is to within ±1.0°C. Software-selectable logging intervals include 1 second, 10 seconds, 1 minute, 5 minutes, 30 minutes, 30 minutes, 1 hour, 6 hours, and 12 hours.
How to use the logger:
Install the FREE software using the Installation Wizard
Connect the logger to your PC's USB port after installing the software.
Launch the TIPTEMP EasyLog Software and follow the instructions to program the logger for Thermocouple input type, Sampling Rate, Deg. C or F and Alarm set point.
Disconnect the logger and place in your desired environment.
When logging is over re-connect USB logger to computer and launch TIPTEMP EasyLog Software.
Follow the simple instructions to extract data, a graph will appear.
Save data file to PC's hard drive for archiving and to open in Excel.
Re-program logger for use again.
When down loading data again, don't forget to create a new data file name or you will erase the previous one
Temperature Sensing Range
-328°F ~ 2272°F (-200°C ~ 1245°C)
Operating Temperature Range
Temperature Accuracy
+/- 4°F (+/- 2°C) typical
Temperature Resolution
0.1°
Temperature Scale
°F and °C
Max Temp
Type of Sensor
Thermocouple
Sensor Wire Length
Sensor Type
Sensor Style
Sensor Dimensions
Probe Length
Sheath Diameter
Sheath Length
Sheath Material
Wire Gauge
Wire Length
Wire Material
Special Limits
Stripped Leads Length
Transition Diameter
Transition Length
Plug Size
Jack Size
Time Constant
Response Time
Number of Measuring Points
Number of Events
Color Change
Number of Sensors
One
Data Points
32,000
Min/ Max Memory
Yes
Recording Rate
Sampling Rate
10s 1m 5m 30m 1hr 6hr or 12hr
Transmission Rate
Exportable Data
Yes
Software Required
Yes - FREE Download
Software Type
Windows 10, 8, 7 (32-bit and 64-Bit Versions)
Network Connectivity
USB
WiFi Network
Dimensions
Weight
.2
Calibration Available
Yes (purchased separately)
Display
None
Display Dimensions
Offset
Power
Battery 1/2 AA ( User Replaceable )
Battery Life
12 Months Typical @ 30 min Recording Interval
Battery Backup
No
Location
Adhesive
Adhesive Type
Shelf Life
Storage Conditions
Humidity Range
Humidity Accuracy
Humidity Resolution
IP Rating
Special Notes
Accepts multiple Thermocouple Types: J-K-T
Part number LASREC007
USB logger supports Type J K and T Thermocouple Probes
Supplied with basic K-type thermocouple rated from -20 to 110°C (-4 to 230°F)