Dual-Purpose Forehead & Surface Temperature Measurement

──────────────────────────

Quick Specs

🌑 Temperature Range: -7°F to 176°F (-22°C to 80°C)

🎯 Forehead Accuracy: ±0.4°F (±0.2°C)

🌑 Accuracy Range: 95°F to 107.6°F (35°C to 42°C)

πŸ“ Distance-to-Spot Ratio: 2:1

πŸ‘€ Forehead Mode: Non-Contact Measurement

🏭 Industry Mode: Surface Temperature Measurement

🚨 High-Temp Alarm: Above 99.5°F (37.5°C)

πŸ”Š Alarm Type: Audible Alert

πŸ”‹ Power: Batteries Included

πŸ’€ Power Management: Automatic Shutoff

──────────────────────────

Related Items & Spare Parts

βš–οΈ Calibration and certification services

🌑 Contact thermometers and temperature probes

πŸ“ˆ Temperature data loggers

πŸ§ͺ Infrared temperature instruments

πŸ”‹ Replacement batteries

🧰 Protective cases and instrument accessories

Explore the related items at the bottom of this page for compatible accessories, replacement parts, and supplies.

──────────────────────────

πŸ›’ Add to Cart Now or πŸ“ž Call 1-800-TIP-TEMP (847-8367) for expert guidance.

IN STOCK

Current Stock: 9

Notable Features

0.5C AccuracyAlerts, AudibleVisual AlertsAuto - OFFBack-LightBatteryBusinessInfraredLCD DisplayNewResidentialSpecial OrderTemperature C/FTT Verified

This non-contact infrared thermometer provides fast temperature measurement without touching the person or surface being checked. It combines a high-accuracy forehead measurement mode with an industry mode for general surface-temperature checks.

Forehead mode provides accuracy of Β±0.4Β°F (Β±0.2Β°C) within the specified clinical range and includes an audible high-temperature alert. The 2:1 distance-to-spot ratio supports close-range surface measurements for maintenance, screening, and general temperature-checking applications.

──────────────────────────

Ideal Applications

πŸ‘€ Non-contact forehead temperature checks

πŸ₯ Medical and healthcare environments

🏒 Workplace temperature screening

🏭 Industrial surface temperature checks

βš™οΈ Equipment troubleshooting

🍽️ Foodservice surface checks

πŸ§ͺ Laboratory and general-purpose measurement

Type of Sensor: IR Thermometer
Temperature Sensing Range: -7 ~ 176Β°F (-22 ~ 80Β°C)
Temperature Accuracy: Accuracy +/- 0.4Β°F (0.2Β°C) of reading from 95 to 107.6Β°F (35 to 42Β°C)
Temperature Resolution: 0.1Β°
Temperature Scale: Β°F or Β°C
Dimensions: 6" x 2" x 1.5"
Weight: 0.25 lbs
Power: (2) AAA BAtteries
Battery Life: ~3000 readings (typical)
IP Rating: IP22
Special Notes: FDA Listed
Display: BackLit LCD
  • (1) Medical Grade IR Thermometer
  • (2) AAA Batteries
  • Expert Technical Support
  • Employee Temperature Log Form
  • Due to today's health concerns this product is not returnable. All sales are final.

Compliance & Risk Mitigation

πŸ‘€ Non-contact design reduces physical contact

🎯 High accuracy within forehead range

🚨 Audible alarm identifies elevated readings

🏭 Separate mode supports surface measurements

πŸ“ Correct measuring distance improves results

πŸ”‹ Auto-off helps preserve battery life

βš–οΈ Periodic calibration supports validation

Forehead and industrial surface modes are intended for different measurement applications and should be used according to the instrument instructions. Infrared readings can be affected by measuring distance, surface characteristics, ambient conditions, and measurement technique. Annual calibration is important for maintaining measurement validation and confirming that the thermometer continues to operate and measure properly.

──────────────────────────

View METINF006 BrochureView METINF006 InstructionsView METINF006 Quick Start Guide

1. Always make sure the probe lens is clean without any damage and the forehead is clean.
*Warning: Choking from swallowing small parts and batteries by children or pets is possible, please keep small parts and batteries at places where children and pets can’t reach.

2. Power on: Press the β€œON/MEM” button

3. Measuring body temperature on the forehead:
*Points for attention:
a. Forehead temperature is displayed in oral mode. This mode converts the forehead temperature to display its "oral-equivalent" value.
b. Before the measurement, the subject should stay in a stable environment for 5 minutes and avoid exercise, bath for 30mins.
c. Remember to keep the forehead area clean and away from sweat, cosmetics and scar while taking temperature.
d. The "Clinical Bias" is -2.5 ~ -3.1Β°F (-1.4 ~ -1.7Β°C).
e. The "Limits of Agreement" is 0.98.
f. The "Repeatability" is 0.36Β°F (0.20Β°C)

4. Measuring surface temperature:
4.1 After power on, press and hold the "ON/MEM" button, and press the "START" button one time for "Infrared thermometer" mode to see icon on your LCD display. In this mode, you can get the target surface temperature.
4.2 When you press the β€œSTART” button, you will get the real time temperature immediately. If you press and hold the β€œSTART” button, the reading of measurement will be continuously updated.
4.3 Applications include temperature measurements for water, milk, cloth, skin or other objects.
* Note: This mode shows the actual and un-adjusted surface temperature which is different from the body temperature.


5. Power off:
5.1 Device will automatically shut off if left idle for more than 1 minute to extend battery life.
5.2 Manually power off the device by pressing the β€œON/MEM” button.