🚦 TTI Freeze Alarm – Below 32°F

$5.95
QuantityPrice
SKU: TIMSEN021

Single-Use Electronic Freeze Indicator with Dual LED Alerts

──────────────────────────

Quick Specs

🌡 Sensing Range:-4°F to 140°F (-20°C to 60°C)

❄️ Freeze Threshold:Below 32°F (0°C)

🚦 LED 1:30 Minutes Below 32°F (0°C)

🚦 LED 2:60 Minutes Below 32°F (0°C)

🎯 Accuracy:±1°F (±0.5°C), Typical

🧪 Sensor:Internal Thermistor

🔋 Battery:Internal, Non-Replaceable

⏳ Battery Life:Approximately 1 Year

🛡️ Protection:IP54 Dust & Splash Resistant

📏 Size:22.6 × 42.3 × 5.6 mm; 6 g

📦 Shelf Life:2 Years

🕒 Cumulative Time:User-Programmable

🏷️ Mounting:Self-Adhesive Backing

📑 Calibration:Certificate Available Separately

──────────────────────────

Related Items & Spare Parts

🚦 Electronic TTIs with alternate alarm thresholds

⬜⬛ Irreversible freeze indication labels

📈 Temperature data loggers for detailed records

🌡 Refrigerated storage temperature monitors

💧 Temperature and humidity monitoring devices

Explore the related items at the bottom of this page for compatible indicators, monitoring instruments, and supplies.

──────────────────────────

🛒 Add to Cart Nowor 📞 Call 1-800-TIP-TEMP (847-8367)for expert guidance.

IN STOCK

Current Stock: 197

Notable Features

0.5C AccuracyVisual AlertsBatteryBusinessCold ChainData LoggingDate & TimeLabel DescendingNew2yr Shelf LifeSpecial OrderThermistor SensorTTITT VerifiedWaterProof

The TTI Electronic Freeze Alarmis a compact, battery-powered time-temperature indicator designed to detect freezing conditions during storage, transportation, and distribution of temperature-sensitive products.

The device monitors exposure to temperatures below 32°F (0°C)and provides two LED alarm stages. The first LED indicates 30 minutes of freezing exposure, while the second indicates 60 minutes, helping personnel identify the duration of potentially damaging cold conditions.

Its self-adhesive backing allows easy attachment to packages, containers, and equipment. The internal thermistor and non-replaceable battery provide standalone monitoring without external power or additional wiring.

──────────────────────────

Ideal Applications

❄️ Freeze-sensitive product shipments

💊 Pharmaceutical cold-chain monitoring

🚚 Refrigerated transportation

🧪 Laboratory samples and diagnostic materials

🏥 Medical supply storage and distribution

📦 Temperature-sensitive packaging

Type of Sensor: Thermistor
Temperature Sensing Range: -4º F ~ 140ºF / -20º C ~ 60º C
Operating Temperature Range: -4º F ~ 140ºF / -20º C ~ 60º C
Temperature Accuracy: +/- 1°F (+/- 0.5°C) typical
Temperature Scale: °F and °C
Dimensions: 22.6mm x 42.3mm x 5.6mm ; 6g
Calibration Available: Certificate of Conformance ( $ Extra )
Power: Non-replaceable Battery
Battery Life: 1 Year
Battery Backup: No
IP Rating: IP54 Dust / Splash Proof
Cumulative Indication Time: User Programmable
Special Notes: Attach to a product using the self-adhesive backing
Adhesive: Yes
Number of Events: Custom
Shelf Life: 2 Year
  • (10) Pc. Minimum
  • TTI Alarm / Singe use
  • Flashing Lights Below 0°C
  • Attach to a product using the self-adhesive backing.
  • Expert Technical Support

Compliance & Risk Mitigation

🚦 Dual LEDs identify freeze exposure stages

❄️ Detects temperatures below freezing

⏱ Tracks 30- and 60-minute alarm thresholds

📋 Supports receiving and shipment inspections

🔋 Verify battery life and shelf life before use

🛡️ IP54 housing resists dust and splashes

📑 Calibration certificate available separately

This single-use electronic indicator provides LED notification of freezing exposure based on preset time-temperature thresholds. It does not prevent freezing or provide a downloadable temperature history. Confirm alarm settings, activation procedures, and suitability for the monitored product before use.

──────────────────────────

Spec Sheet & Instructions

How to use

  1. To activate, press and hold the button for >3.5 seconds until the green ‘Power on’ LED flashes 3 times.
  2. Once the indicator has been activated, the "Power On" LED will flash every 8 seconds.
  3. The device starts monitoring temperature after the 30-minute start delay.
  4. If no temperature breach has occurred, the green ‘Power on’ LED will flash.
  5. When the temperature drops below 0°C for more than 30 minutes single event the red ’30 minute’ LED will flash.
  6. When the temperature drops below 0°C for more than 60 minutes single event, the red ’60 minute’ LED will flash.